Search results for "HIGH DEFINITION"
showing 10 items of 16 documents
Role of lignin and sodium carbonate on the swelling behavior of black liquor droplets during combustion
2018
AbstractA partial removal of lignin from black liquor (BL) by carbonation and lignin precipitation was studied. In lignin-lean BL droplets during combustion in a laboratory furnace at 800°C in stagnant air, the maximum swelling was decreased. This observation was interpreted as showing that the lignin content decrement is due mainly to removal of higher molar mass (HMM) lignin and that the Na2CO3content of the BL is increased. Stepwise precipitation experiments with industrial softwood and hardwood kraft BLs by carbonation (resulting in pH decrement from 13 to 9) indicated that a fraction of HMM lignin (MM >10 kDa) with a higher amount of carbohydrates precipitated more prominently and e…
High-definition transcranial direct current stimulation to both primary motor cortices improves unimanual and bimanual dexterity.
2017
While most research on brain stimulation with transcranial direct current stimulation (tDCS) targets unimanual motor tasks, little is known about its effects on bimanual motor performance. This study aims to investigate the effects of tDCS on unimanual as well as bimanual motor dexterity. We examined the effects of bihemispheric anodal high-definition tDCS (HD-atDCS) on both primary motor cortices (M1) applied concurrent with unimanual and bimanual motor training. We then measured the effects with the Purdue Pegboard Test (PPT) and compared them to a sham stimulation. Between a pretest and posttest, 31 healthy, right-handed participants practiced the PPT on three consecutive days and receiv…
High definition plus colonoscopy combined with i-scan tone enhancement vs. high definition colonoscopy for colorectal neoplasia: A randomized trial
2014
High definition endoscopy is the accepted standard in colonoscopy. However, an important problem is missed polyps.Our objective was to assess the additional adenoma detection rate between high definition colonoscopy with tone enhancement (digital chromoendoscopy) vs. white light high definition colonoscopy.In this prospective randomized trial patients were included to undergo a tandem colonoscopy. The first exam was a white light colonoscopy with removal of all visualized polyps. The second examination was randomly assigned in a 1:1 ratio as either again white light colonoscopy (Group A) or colonoscopy with tone enhancement (Group B). Primary endpoint was the adenoma detection rate during t…
Advanced imaging of the gastrointestinal tract: research vs. clinical tools?
2009
Diagnostic endoscopy has moved forward considerably in the recent years. Still, three major needs have to be satisfied: endoscopy should be able to detect a lesion, characterize the lesion, and then its nature should be confirmed. These steps should ideally translate into an immediate therapeutic decision.High definition endoscopy has optimized our endoscopic view onto the mucosa and can be combined with digital surface enhancement modalities. Chromoendoscopy still holds a place to detect especially flat lesions in high-risk patients such as ulcerative colitis. Digital chromoendoscopy techniques such as narrow band imaging, i-scan, or Fuji intelligent chromo endoscopy offer new possibilitie…
Educational value of surgical videos on YouTube: quality assessment of laparoscopic appendectomy videos by senior surgeons vs. novice trainees
2019
Background To prepare for surgery, surgeons often recur to surgical videos, with YouTube being reported as the preferred source. This study aimed to compare the evaluation of three surgical trainees and three senior surgeons of the 25 most viewed laparoscopic appendectomy videos listed on YouTube. Additionally, we assessed the video conformity to the published guidelines on how to report laparoscopic surgery videos (LAP-VEGaS). Methods Based on the number of visualization, the 25 most viewed videos on laparoscopic appendectomy uploaded on YouTube between 2010 and 2018 were selected. Videos were evaluated on the surgical technical performance (GOALS score), critical view of safety (CVS), and…
High-Definition Imaging in Spinal Neuroendoscopy
2010
BACKGROUND Spinal endoscopy is still under controversial discussion. An often acclaimed critic is the poor endoscopic image quality in comparison with the microscope. Since high-definition digital cameras have recently been introduced into spinal neuroendoscopy, the aim of the current study is to examine whether superior image quality has a relevant impact on intraoperativen orientation. MATERIAL AND METHODS A lumbar endoscopic discectomy was recorded simultaneously in High-Definition resolution (HD) and Standard-Definition resolution (SD). 10 experienced spinal surgeons were asked to identify predefined as well as not predefined anatomic structures in HD and SD resolution. Additionally, th…
The Quest for Global Safety
2007
The authors present a systematic study on the factors that have influence on the establishment of the safety conditions ensuring the rise of Global Earthing Systems. Starting from the definition of Global Earthing System given by CENELEC Document HD 637 SI and from the results of the studies done on the last years on the interconnected earthing systems inside MV networks, the paper proposes some directions of deepening on the topic of Global Safety. Some of the themes whom the paper deals with are: the correct definition of proximity, interconnection and quasi-equipotentiality of the earth electrodes belonging to a Global Earthing System; the influence of the presence of HV/MV stations on h…
ATLAS
2020
The book provides a comprehensive overview of high-resolution and high-definition anorectal manometry (HRAM/HDAM), showing the possible benefits of a wider use of these techniques in clinical practice, as well as their limitations. Although these techniques provide fresh insights into anorectal function and offer a new perspective on the pathophysiologic mechanisms of many defecation disturbances, there is a need to clarify whether their use has beneficial effects on clinical management compared to conventional manometry. There is still a considerable way to go to gain the clinical diffusion of esophageal HRM, which has become the gold standard in studying esophageal motility. Indeed, many …
3D high definition video coding on a GPU-based heterogeneous system
2013
H.264/MVC is a standard for supporting the sensation of 3D, based on coding from 2 (stereo) to N views. H.264/MVC adopts many coding options inherited from single view H.264/AVC, and thus its complexity is even higher, mainly because the number of processing views is higher. In this manuscript, we aim at an efficient parallelization of the most computationally intensive video encoding module for stereo sequences. In particular, inter prediction and its collaborative execution on a heterogeneous platform. The proposal is based on an efficient dynamic load balancing algorithm and on breaking encoding dependencies. Experimental results demonstrate the proposed algorithm's ability to reduce the…
Tracking Changes in Frontal Lobe Hemodynamic Response in Individual Adults With Developmental Language Disorder Following HD tDCS Enhanced Phonologic…
2020
Background: Current research suggests a neurobiological marker of developmental language disorder (DLD) in adolescents and young adults may be an atypical neural profile coupled with behavioral performance that overlaps with that of normal controls. Although many imaging techniques are not suitable for the study of speech and language processing in DLD populations, fNIRS may be a viable option. In this study we asked if fNIRS can be used to identify atypical cortical activation patterns in individual adults with DLD and track potential changes in cortical activation patterns following a phonological working memory training protocol enhanced with anodal HD tDCS stimulation to the presuppleme…